Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 281
Filtrar
1.
Heart Rhythm ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38670247

RESUMO

BACKGROUND: Implantable cardiac defibrillator (ICD) implantation can protect against sudden cardiac death (SCD) after a myocardial infarction. However, improved risk stratification for device requirement is still needed. OBJECTIVE: To improve assessment of post-infarct ventricular electro-pathology and prediction of appropriate ICD therapy by combining late gadolinium enhancement (LGE) and advanced computational modelling. METHODS: ADAS LV and custom-made software was used to generate 3D patient-specific ventricular models in a prospective cohort of post-infarct patients (n=40) having undergone LGE imaging pre-ICD implantation. Corridor metrics and 3D surface features were computed from LGE images. The Virtual Induction and Treatment of Arrhythmias (VITA) framework was applied to patient-specific models to comprehensively probe the vulnerability of the scar substrate to sustaining reentrant circuits. Imaging and VITA metrics, related to the numbers of induced VTs and their corresponding round trip times (RTTs), were compared with ICD therapy during follow-up. RESULTS: Patients with an event (n=17) had a larger interface between healthy-scar and higher VITA metrics. Cox-regression demonstrated a significant independent association with an event: interface (HR 2.79; 1.44-5.44, p < .01), unique VTs (HR 1.67; CI 1.04-2.68, p = .03), mean RTT (HR 2.14; CI 1.11-4.12, p = .02), maximum RTT (HR 2.13; CI 1.19-3.81, p = .01). CONCLUSION: Detailed quantitative analysis of LGE based scarmaps, combined with advanced computational modeling, is able to accurately predict ICD therapy and could facilitate early identification of high-risk patients in addition to LVEF.

2.
Front Cardiovasc Med ; 11: 1359715, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38596691

RESUMO

Background: A reduced left atrial (LA) strain correlates with the presence of atrial fibrillation (AF). Conventional atrial strain analysis uses two-dimensional (2D) imaging, which is, however, limited by atrial foreshortening and an underestimation of through-plane motion. Retrospective gated computed tomography (RGCT) produces high-fidelity three-dimensional (3D) images of the cardiac anatomy throughout the cardiac cycle that can be used for estimating 3D mechanics. Its feasibility for LA strain measurement, however, is understudied. Aim: The aim of this study is to develop and apply a novel workflow to estimate 3D LA motion and calculate the strain from RGCT imaging. The utility of global and regional strains to separate heart failure in patients with reduced ejection fraction (HFrEF) with and without AF is investigated. Methods: A cohort of 30 HFrEF patients with (n = 9) and without (n = 21) AF underwent RGCT prior to cardiac resynchronisation therapy. The temporal sparse free form deformation image registration method was optimised for LA feature tracking in RGCT images and used to estimate 3D LA endocardial motion. The area and fibre reservoir strains were calculated over the LA body. Universal atrial coordinates and a human atrial fibre atlas enabled the regional strain calculation and the fibre strain calculation along the local myofibre orientation, respectively. Results: It was found that global reservoir strains were significantly reduced in the HFrEF + AF group patients compared with the HFrEF-only group patients (area strain: 11.2 ± 4.8% vs. 25.3 ± 12.6%, P = 0.001; fibre strain: 4.5 ± 2.0% vs. 15.2 ± 8.8%, P = 0.001), with HFrEF + AF patients having a greater regional reservoir strain dyssynchrony. All regional reservoir strains were reduced in the HFrEF + AF patient group, in whom the inferior wall strains exhibited the most significant differences. The global reservoir fibre strain and LA volume + posterior wall reservoir fibre strain exceeded LA volume alone and 2D global longitudinal strain (GLS) for AF classification (area-under-the-curve: global reservoir fibre strain: 0.94 ± 0.02, LA volume + posterior wall reservoir fibre strain: 0.95 ± 0.02, LA volume: 0.89 ± 0.03, 2D GLS: 0.90 ± 0.03). Conclusion: RGCT enables 3D LA motion estimation and strain calculation that outperforms 2D strain metrics and LA enlargement for AF classification. Differences in regional LA strain could reflect regional myocardial properties such as atrial fibrosis burden.

4.
Heart Rhythm ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38354872

RESUMO

BACKGROUND: Machine learning (ML) models have been proposed to predict risk related to transvenous lead extraction (TLE). OBJECTIVE: The purpose of this study was to test whether integrating imaging data into an existing ML model increases its ability to predict major adverse events (MAEs; procedure-related major complications and procedure-related deaths) and lengthy procedures (≥100 minutes). METHODS: We hypothesized certain features-(1) lead angulation, (2) coil percentage inside the superior vena cava (SVC), and (3) number of overlapping leads in the SVC-detected from a pre-TLE plain anteroposterior chest radiograph (CXR) would improve prediction of MAE and long procedural times. A deep-learning convolutional neural network was developed to automatically detect these CXR features. RESULTS: A total of 1050 cases were included, with 24 MAEs (2.3%) . The neural network was able to detect (1) heart border with 100% accuracy; (2) coils with 98% accuracy; and (3) acute angle in the right ventricle and SVC with 91% and 70% accuracy, respectively. The following features significantly improved MAE prediction: (1) ≥50% coil within the SVC; (2) ≥2 overlapping leads in the SVC; and (3) acute lead angulation. Balanced accuracy (0.74-0.87), sensitivity (68%-83%), specificity (72%-91%), and area under the curve (AUC) (0.767-0.962) all improved with imaging biomarkers. Prediction of lengthy procedures also improved: balanced accuracy (0.76-0.86), sensitivity (75%-85%), specificity (63%-87%), and AUC (0.684-0.913). CONCLUSION: Risk prediction tools integrating imaging biomarkers significantly increases the ability of ML models to predict risk of MAE and long procedural time related to TLE.

5.
Circ Arrhythm Electrophysiol ; 17(3): e012446, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38258308

RESUMO

BACKGROUND: Antimicrobial envelopes reduce the incidence of cardiac implantable electronic device infections, but their cost restricts routine use in the United Kingdom. Risk scoring could help to identify which patients would most benefit from this technology. METHODS: A novel risk score (BLISTER [Blood results, Long procedure time, Immunosuppressed, Sixty years old (or younger), Type of procedure, Early re-intervention, Repeat procedure]) was derived from multivariate analysis of factors associated with cardiac implantable electronic device infection. Diagnostic utility was assessed against the existing PADIT score (Prior procedure, Age, Depressed renal function, Immunocompromised, Type of procedure) in both standard and high-risk external validation cohorts, and cost-utility models examined different BLISTER and PADIT score thresholds for TYRX (Medtronic; Minneapolis, MN) antimicrobial envelope allocation. RESULTS: In a derivation cohort (n=7383), cardiac implantable electronic device infection occurred in 59 individuals within 12 months of a procedure (event rate, 0.8%). In addition to the PADIT score constituents, lead extraction (hazard ratio, 3.3 [95% CI, 1.9-6.1]; P<0.0001), C-reactive protein >50 mg/L (hazard ratio, 3.0 [95% CI, 1.4-6.4]; P=0.005), reintervention within 2 years (hazard ratio, 10.1 [95% CI, 5.6-17.9]; P<0.0001), and top-quartile procedure duration (hazard ratio, 2.6 [95% CI, 1.6-4.1]; P=0.001) were independent predictors of infection. The BLISTER score demonstrated superior discriminative performance versus PADIT in the standard risk (n=2854, event rate: 0.8%, area under the curve, 0.82 versus 0.71; P=0.001) and high-risk validation cohorts (n=1961, event rate: 2.0%, area under the curve, 0.77 versus 0.69; P=0.001), and in all patients (n=12 198, event rate: 1%, area under the curve, 0.8 versus 0.75, P=0.002). In decision-analytic modeling, the optimum scenario assigned antimicrobial envelopes to patients with BLISTER scores ≥6 (10.8%), delivering a significant reduction in infections (relative risk reduction, 30%; P=0.036) within the National Institute for Health and Care Excellence cost-utility thresholds (incremental cost-effectiveness ratio, £18 446). CONCLUSIONS: The BLISTER score (https://qxmd.com/calculate/calculator_876/the-blister-score-for-cied-infection) was a valid predictor of cardiac implantable electronic device infection, and could facilitate cost-effective antimicrobial envelope allocation to high-risk patients.


Assuntos
Anti-Infecciosos , Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardiopatias/complicações , Antibacterianos/uso terapêutico , Fatores de Risco , Eletrônica , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Marca-Passo Artificial/efeitos adversos
6.
Circ Cardiovasc Qual Outcomes ; 17(1): e010533, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37929587

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) is frequently undertaken in patients with ischemic left ventricular systolic dysfunction. The REVIVED (Revascularization for Ischemic Ventricular Dysfunction)-BCIS2 (British Cardiovascular Society-2) trial concluded that PCI did not reduce the incidence of all-cause death or heart failure hospitalization; however, patients assigned to PCI reported better initial health-related quality of life than those assigned to optimal medical therapy (OMT) alone. The aim of this study was to assess the cost-effectiveness of PCI+OMT compared with OMT alone. METHODS: REVIVED-BCIS2 was a prospective, multicenter UK trial, which randomized patients with severe ischemic left ventricular systolic dysfunction to either PCI+OMT or OMT alone. Health care resource use (including planned and unplanned revascularizations, medication, device implantation, and heart failure hospitalizations) and health outcomes data (EuroQol 5-dimension 5-level questionnaire) on each patient were collected at baseline and up to 8 years post-randomization. Resource use was costed using publicly available national unit costs. Within the trial, mean total costs and quality-adjusted life-years (QALYs) were estimated from the perspective of the UK health system. Cost-effectiveness was evaluated using estimated mean costs and QALYs in both groups. Regression analysis was used to adjust for clinically relevant predictors. RESULTS: Between 2013 and 2020, 700 patients were recruited (mean age: PCI+OMT=70 years, OMT=68 years; male (%): PCI+OMT=87, OMT=88); median follow-up was 3.4 years. Over all follow-ups, patients undergoing PCI yielded similar health benefits at higher costs compared with OMT alone (PCI+OMT: 4.14 QALYs, £22 352; OMT alone: 4.16 QALYs, £15 569; difference: -0.015, £6782). For both groups, most health resource consumption occurred in the first 2 years post-randomization. Probabilistic results showed that the probability of PCI being cost-effective was 0. CONCLUSIONS: A minimal difference in total QALYs was identified between arms, and PCI+OMT was not cost-effective compared with OMT, given its additional cost. A strategy of routine PCI to treat ischemic left ventricular systolic dysfunction does not seem to be a justifiable use of health care resources in the United Kingdom. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01920048.


Assuntos
Doença da Artéria Coronariana , Insuficiência Cardíaca , Intervenção Coronária Percutânea , Disfunção Ventricular Esquerda , Idoso , Humanos , Masculino , Doença da Artéria Coronariana/terapia , Análise de Custo-Efetividade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/terapia , Feminino
7.
medRxiv ; 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38106113

RESUMO

Background: Studies have reported that female sex predicts superior cardiac resynchronization therapy (CRT) response. One theory is that this association is related to smaller female heart size, thus increased "relative dyssynchrony" at given QRS durations (QRSd). Objective: To investigate the mechanisms of sex-specific CRT response relating to heart size, relative dyssynchrony, cardiomyopathy type, QRS morphology, and other patient characteristics. Methods: A post-hoc analysis of the MORE-CRT MPP trial (n=3739, 28% female), with a sub-group analysis of patients with non-ischaemic cardiomyopathy (NICM) and left bundle branch block (LBBB) (n=1308, 41% female) to control for confounding characteristics. A multivariable analysis examined predictors of response to 6 months of conventional CRT, including sex and relative dyssynchrony, measured by QRSd/LVEDV (left ventricular end-diastolic volume). Results: Females had a higher CRT response rate than males (70.1% vs. 56.8%, p<0.0001). Subgroup analysis: Regression analysis of the NICM LBBB subgroup identified QRSd/LVEDV, but not sex, as a modifier of CRT response (p<0.0039). QRSd/LVEDV was significantly higher in females (0.919) versus males (0.708, p<0.001). CRT response was 78% for female patients with QRSd/LVEDV>median value, compared to 68% < median value (p=0.012). Association between CRT response and QRSd/LVEDV was strongest at QRSd<150ms. Conclusions: In the NICM LBBB population, increased relative dyssynchrony in females, who have smaller heart sizes than their male counterparts, is a driver of sex-specific CRT response, particularly at QRSd <150ms. Females may benefit from CRT at a QRSd <130ms, opening the debate on whether sex-specific QRSd cut-offs or QRS/LVEDV measurement should be incorporated into clinical guidelines.

9.
J Cardiovasc Electrophysiol ; 34(12): 2590-2598, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37814470

RESUMO

BACKGROUND: The Wireless Stimulation Endocardially for CRT (WiSE-CRT) system is a novel technology used to treat patients with dyssynchronous heart failure (HF) by providing leadless cardiac resynchronization therapy (CRT). Observational studies have demonstrated its safety and efficacy profile, however, the treatment cost-effectiveness has not previously been examined. METHODS: A cost-effectiveness evaluation of the WiSE-CRT System was performed using a cohort-based economic model adopting a "proportion in state" structure. In addition to the primary analysis, scenario analyses and sensitivity analyses were performed to test for uncertainty in input parameters. Outcomes were quantified in terms of quality-adjusted life year (QALY) differences. RESULTS: The primary analysis demonstrated that treatment with the WiSE-CRT system is likely to be cost-effective over a lifetime horizon at a QALY reimbursement threshold of £20 000, with a net monetary benefit (NMB) of £3781 per QALY. Cost-effectiveness declines at time horizons shorter than 10 years. Sensitivity analyses demonstrated that average system battery life had the largest impact on potential cost-effectiveness. CONCLUSION: Within the model limitations, these findings support the use of WiSE-CRT in indicated patients from an economic standpoint. However, improving battery technology should be prioritized to maximize cost-effectiveness in times when health services are under significant financial pressures.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/economia , Análise de Custo-Efetividade , Insuficiência Cardíaca/terapia , Resultado do Tratamento
10.
Artigo em Inglês | MEDLINE | ID: mdl-37870689

RESUMO

Conduction system pacing (CSP) has the potential to achieve physiological-paced activation by pacing the ventricular conduction system. Before CSP is adopted in standard clinical practice, large, randomised, and multi-centre trials are required to investigate CSP safety and efficacy compared to standard biventricular pacing (BVP). Furthermore, there are unanswered questions about pacing thresholds required to achieve optimal pacing delivery while preventing device battery draining, and about which patient groups are more likely to benefit from CSP rather than BVP. In silico studies have been increasingly used to investigate mechanisms underlying changes in cardiac function in response to pathologies and treatment. In the context of CSP, they have been used to improve our understanding of conduction system capture to optimise CSP delivery and battery life, and noninvasively compare different pacing methods on different patient groups. In this review, we discuss the in silico studies published to date investigating different aspects of CSP delivery.

11.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37757839

RESUMO

AIMS: While numerous studies have demonstrated favourable safety and efficacy of the excimer laser sheath for transvenous lead extraction (TLE) in smaller cohorts, comprehensive large-scale investigations with contemporary data remain scarce. This study aims to evaluate the safety and performance of laser-assisted TLE through a meta-analysis of contemporary data. METHODS AND RESULTS: A systematic literature search was conducted to identify articles that assessed the safety and performance of the spectranetics laser sheath (SLS) II and GlideLight Excimer laser sheaths in TLE procedures between 1 April 2016 and 31 March 2021. Safety outcomes included procedure-related death and major/minor complications. Performance outcomes included procedural and clinical success rates. A random-effects, inverse-variance-weighting meta-analysis was performed to obtain the weighted average of the evaluated outcomes. In total, 17 articles were identified and evaluated, including 1729 patients with 2887 leads. Each patient, on average, had 2.3 ± 0.3 leads with a dwell time of 7.9 ± 3.0 years. The TLE procedural successes rate was 96.8% [1440/1505; 95% CI: (94.9-98.2%)] per patient and 96.3% [1447/1501; 95% CI: (94.8-97.4%)] per lead, and the clinical success rate per patient was 98.3% [989/1010, 95% CI: (97.4-99.0%)]. The procedure-related death rate was 0.08% [7/1729, 95% CI: (0.00%, 0.34%)], with major and minor complication rates of 1.9% [41/1729; 95% CI: (1.2-2.8%)] and 1.9% [58/1729; 95% CI: (0.8-3.6%)], respectively. CONCLUSION: This meta-analysis demonstrated that excimer laser sheath-assisted TLE has high success and low procedural mortality rates. It provides clinicians with a reliable and valuable resource for extracting indwelling cardiac leads which require advanced extraction techniques.


Assuntos
Remoção de Dispositivo , Humanos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Lasers de Excimer/efeitos adversos , Marca-Passo Artificial , Estudos Retrospectivos , Resultado do Tratamento
12.
Europace ; 25(10)2023 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-37776313

RESUMO

AIMS: To assess the impact of MultiPoint™ Pacing (MPP) in cardiac resynchronization therapy (CRT) non-responders after 6 months of standard biventricular pacing (BiVP). METHODS AND RESULTS: The trial enrolled 5850 patients who planned to receive a CRT device. The echocardiography core laboratory assessed CRT response before implant and after 6 months of BiVP; non-response to BiVP was defined as <15% relative reduction in left ventricular end-systolic volume (LVESV). Echocardiographic non-responders were randomized in a 1:1 ratio to receive MPP (541 patients) or continued BiVP (570 patients) for an additional 6 months and evaluated the conversion rate to the echocardiographic response. The characteristics of both groups at randomization were comparable. The percentage of non-responder patients who became responders to CRT therapy was 29.4% in the MPP arm and 30.4% in the BIVP arm (P = 0.743). In patients with ≥30 mm spacing between the two left ventricular pacing sites (MPP-AS), identified during the first phase as a potential beneficial subgroup, no significant difference in the conversion rate was observed. CONCLUSION: Our trial shows that ∼30% of patients, who do not respond to CRT in the first 6 months, experience significant reverse remodelling in the following 6 months. This finding suggests that CRT benefit may be delayed or slowly incremental in a relevant proportion of patients and that the percentage of CRT responders may be higher than what has been described in short-/middle-term studies. MultiPoint™ Pacing does not improve CRT response in non-responders to BiVP, even with MPP-AS.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Resultado do Tratamento , Estudos Prospectivos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Dispositivos de Terapia de Ressincronização Cardíaca , Função Ventricular Esquerda/fisiologia
13.
Front Cardiovasc Med ; 10: 1211560, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37608808

RESUMO

Arrhythmia is an extremely common finding in patients receiving cardiac resynchronisation therapy (CRT). Despite this, in the majority of randomised trials testing CRT efficacy, patients with a recent history of arrhythmia were excluded. Most of our knowledge into the management of arrhythmia in CRT is therefore based on arrhythmia trials in the heart failure (HF) population, rather than from trials dedicated to the CRT population. However, unique to CRT patients is the aim to reach as close to 100% biventricular pacing (BVP) as possible, with HF outcomes greatly influenced by relatively small changes in pacing percentage. Thus, in comparison to the average HF patient, there is an even greater incentive for controlling arrhythmia, to achieve minimal interference with the effective delivery of BVP. In this review, we examine both atrial and ventricular arrhythmias, addressing their impact on CRT, and discuss the available evidence regarding optimal arrhythmia management in this patient group. We review pharmacological and procedural-based approaches, and lastly explore novel ways of harnessing device data to guide treatment of arrhythmia in CRT.

15.
Circulation ; 148(11): 862-871, 2023 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-37555345

RESUMO

BACKGROUND: Ventricular arrhythmia is an important cause of mortality in patients with ischemic left ventricular dysfunction. Revascularization with coronary artery bypass graft or percutaneous coronary intervention is often recommended for these patients before implantation of a cardiac defibrillator because it is assumed that this may reduce the incidence of fatal and potentially fatal ventricular arrhythmias, although this premise has not been evaluated in a randomized trial to date. METHODS: Patients with severe left ventricular dysfunction, extensive coronary disease, and viable myocardium were randomly assigned to receive either percutaneous coronary intervention (PCI) plus optimal medical and device therapy (OMT) or OMT alone. The composite primary outcome was all-cause death or aborted sudden death (defined as an appropriate implantable cardioverter defibrillator therapy or a resuscitated cardiac arrest) at a minimum of 24 months, analyzed as time to first event on an intention-to-treat basis. Secondary outcomes included cardiovascular death or aborted sudden death, appropriate implantable cardioverter defibrillator (ICD) therapy or sustained ventricular arrhythmia, and number of appropriate ICD therapies. RESULTS: Between August 28, 2013, and March 19, 2020, 700 patients were enrolled across 40 centers in the United Kingdom. A total of 347 patients were assigned to the PCI+OMT group and 353 to the OMT alone group. The mean age of participants was 69 years; 88% were male; 56% had hypertension; 41% had diabetes; and 53% had a clinical history of myocardial infarction. The median left ventricular ejection fraction was 28%; 53.1% had an implantable defibrillator inserted before randomization or during follow-up. All-cause death or aborted sudden death occurred in 144 patients (41.6%) in the PCI group and 142 patients (40.2%) in the OMT group (hazard ratio, 1.03 [95% CI, 0.82-1.30]; P=0.80). There was no between-group difference in the occurrence of any of the secondary outcomes. CONCLUSIONS: PCI was not associated with a reduction in all-cause mortality or aborted sudden death. In patients with ischemic cardiomyopathy, PCI is not beneficial solely for the purpose of reducing potentially fatal ventricular arrhythmias. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01920048.


Assuntos
Desfibriladores Implantáveis , Disfunção Ventricular Esquerda , Humanos , Masculino , Idoso , Feminino , Volume Sistólico , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Função Ventricular Esquerda , Arritmias Cardíacas/etiologia , Disfunção Ventricular Esquerda/etiologia , Desfibriladores Implantáveis/efeitos adversos , Resultado do Tratamento
16.
Artigo em Inglês | MEDLINE | ID: mdl-37427300

RESUMO

Leadless pacing is a rapidly growing field. Initially designed to provide right ventricular pacing for those who were contraindicated for conventional devices, the technology is growing to explore the potential benefit of avoiding long-term transvenous leads in any patient who requires pacing. In this review, we first examine the safety and performance of leadless pacing devices. We then review the evidence for their use in special populations, such as patients with high risk of device infection, patients on haemodialysis, and patients with vasovagal syncope who represent a younger population who may wish to avoid transvenous pacing. We also summarise the evidence for leadless cardiac resynchronisation therapy and conduction system pacing and discuss the challenges of managing issues, such as system revisions, end of battery life and extractions. Finally, we discuss future directions in the field, such as completely leadless cardiac resynchronisation therapy-defibrillator devices and whether leadless pacing has the potential to become a first-line therapy in the near future.

17.
Heart Rhythm ; 20(12): 1629-1636, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37516414

RESUMO

BACKGROUND: Biventricular endocardial pacing (BiV-endo) and left bundle branch area pacing (LBBAP) are novel methods of delivering cardiac resynchronization therapy. These techniques are associated with improved activation times and acute hemodynamic response compared with conventional biventricular epicardial pacing (BiV-epi); however, the effects on repolarization and arrhythmic risk are unknown. OBJECTIVE: The purpose of this study was to compare the effects of temporary BiV-epi, BiV-endo, and LBBAP on epicardial left ventricular (LV) repolarization using electrocardiographic imaging (ECGi). METHODS: Eleven patients indicated for cardiac resynchronization therapy underwent a temporary pacing protocol with ECGi. BiV-endo was delivered via endocardial stimulation of the LV lateral wall. LBBAP was delivered by pacing the LV septum. Epicardial LV repolarization time (LVRT-95; time taken for 95% of the LV to repolarize), LV RT dispersion, mean LV activation recovery interval (ARI), LV ARI dispersion, and RT gradients were calculated. RESULTS: The protocol was completed in 10 patients. During LBBAP, there were significant reductions in LVRT-95 (94.9 ± 17.4 ms vs 125.0 ± 29.4 ms; P = .03) and LV RT dispersion (29.4 ± 6.3 ms vs 40.8 ± 11.4 ms; P = .015) compared with BiV-epi. In contrast, there were no significant differences between baseline, BiV-epi, or BiV-endo. There was a nonsignificant reduction in mean RT gradients between LBBAP and baseline rhythm (0.74 ± 0.22 ms/mm vs 1.01 ± 0.31 ms/mm; P = .07). There were no significant differences in mean LV ARI or LV ARI dispersion between groups. CONCLUSION: Temporary LBBAP reduces epicardial dispersion of repolarization compared with conventional BiV-epi. Further study is required to determine whether these repolarization changes on ECGi translate into a reduced risk of ventricular arrhythmia in clinical practice.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Septo Interventricular , Humanos , Terapia de Ressincronização Cardíaca/métodos , Sistema de Condução Cardíaco , Arritmias Cardíacas/terapia , Ventrículos do Coração , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
18.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37523771

RESUMO

BACKGROUND: Leadless pacemakers (LPs) may mitigate the risk of lead failure and pocket infection related to conventional transvenous pacemakers. Atrial LPs are currently being investigated. However, the optimal and safest implant site is not known. OBJECTIVES: We aimed to evaluate the right atrial (RA) anatomy and the adjacent structures using complementary analytic models [gross anatomy, cardiac magnetic resonance imaging (MRI), and computer simulation], to identify the optimal safest location to implant an atrial LP human. METHODS AND RESULTS: Wall thickness and anatomic relationships of the RA were studied in 45 formalin-preserved human hearts. In vivo RA anatomy was assessed in 100 cardiac MRI scans. Finally, 3D collision modelling was undertaken assessing for mechanical device interaction. Three potential locations for an atrial LP were identified; the right atrial appendage (RAA) base, apex, and RA lateral wall. The RAA base had a wall thickness of 2.7 ± 1.6 mm, with a low incidence of collision in virtual implants. The anteromedial recess of the RAA apex had a wall thickness of only 1.3 ± 0.4 mm and minimal interaction in the collision modelling. The RA lateral wall thickness was 2.6 ± 0.9 mm but is in close proximity to the phrenic nerve and sinoatrial artery. CONCLUSIONS: Based on anatomical review and 3D modelling, the best compromise for an atrial LP implantation may be the RAA base (low incidence of collision, relatively thick myocardial tissue, and without proximity to relevant epicardial structures); the anteromedial recess of the RAA apex and lateral wall are alternate sites. The mid-RAA, RA/superior vena cava junction, and septum appear to be sub-optimal fixation locations.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Veia Cava Superior , Simulação por Computador , Lipopolissacarídeos , Estimulação Cardíaca Artificial/métodos , Átrios do Coração
19.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37421339

RESUMO

AIMS: Substrate assessment of scar-mediated ventricular tachycardia (VT) is frequently performed using late gadolinium enhancement (LGE) images. Although this provides structural information about critical pathways through the scar, assessing the vulnerability of these pathways for sustaining VT is not possible with imaging alone.This study evaluated the performance of a novel automated re-entrant pathway finding algorithm to non-invasively predict VT circuit and inducibility. METHODS: Twenty post-infarct VT-ablation patients were included for retrospective analysis. Commercially available software (ADAS3D left ventricular) was used to generate scar maps from 2D-LGE images using the default 40-60 pixel-signal-intensity (PSI) threshold. In addition, algorithm sensitivity for altered thresholds was explored using PSI 45-55, 35-65, and 30-70. Simulations were performed on the Virtual Induction and Treatment of Arrhythmias (VITA) framework to identify potential sites of block and assess their vulnerability depending on the automatically computed round-trip-time (RTT). Metrics, indicative of substrate complexity, were correlated with VT-recurrence during follow-up. RESULTS: Total VTs (85 ± 43 vs. 42 ± 27) and unique VTs (9 ± 4 vs. 5 ± 4) were significantly higher in patients with- compared to patients without recurrence, and were predictive of recurrence with area under the curve of 0.820 and 0.770, respectively. VITA was robust to scar threshold variations with no significant impact on total and unique VTs, and mean RTT between the four models. Simulation metrics derived from PSI 45-55 model had the highest number of parameters predictive for post-ablation VT-recurrence. CONCLUSION: Advanced computational metrics can non-invasively and robustly assess VT substrate complexity, which may aid personalized clinical planning and decision-making in the treatment of post-infarction VT.


Assuntos
Cicatriz , Simulação por Computador , Taquicardia Ventricular , Humanos , Algoritmos , Ablação por Cateter , Cicatriz/complicações , Infarto do Miocárdio/complicações , Estudos Retrospectivos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Reprodutibilidade dos Testes , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais
20.
Heart Rhythm ; 20(11): 1481-1488, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37453603

RESUMO

BACKGROUND: The WiSE-CRT System (EBR systems, Sunnyvale, CA) permits leadless left ventricular pacing. Currently, no intraprocedural guidance is used to target optimal electrode placement while simultaneously guiding acoustic transmitter placement in close proximity to the electrode to ensure adequate power delivery. OBJECTIVE: The purpose of this study was to assess the use of computed tomography (CT) anatomy, dynamic perfusion and mechanics, and predicted activation pattern to identify both the optimal electrode and transmitter locations. METHODS: A novel CT protocol was developed using preprocedural imaging and simulation to identify target segments (TSs) for electrode implantation, with late electrical and mechanical activation, with ≥5 mm wall thickness without perfusion defects. Modeling of the acoustic intensity from different transmitter implantation sites to the TSs was used to identify the optimal transmitter location. During implantation, TSs were overlaid on fluoroscopy to guide optimal electrode location that were evaluated by acute hemodynamic response (AHR) by measuring the maximal rate of left ventricular pressure rise with biventricular pacing. RESULTS: Ten patients underwent the implantation procedure. The transmitter could be implanted within the recommended site on the basis of preprocedural analysis in all patients. CT identified a mean of 4.8 ± 3.5 segments per patient with wall thickness < 5 mm. During electrode implantation, biventricular pacing within TSs resulted in a significant improvement in AHR vs non-TSs (25.5% ± 8.8% vs 12.9% ± 8.6%; P < .001). Pacing in CT-identified scar resulted in either failure to capture or minimal AHR improvement. The electrode was targeted to the TSs in all patients and was implanted in the TSs in 80%. CONCLUSION: Preprocedural imaging and modeling data with intraprocedural guidance can successfully guide WiSE-CRT electrode and transmitter implantation to allow optimal AHR and adequate power delivery.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Terapia de Ressincronização Cardíaca/métodos , Eletrodos , Tomografia Computadorizada por Raios X , Perfusão , Resultado do Tratamento , Ventrículos do Coração/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...